Cooling Mode Setting Method
Setting Key Principle:
Setting Method:
Usage Case:
Control the cabinet radiator. The radiator stops working when the temperature drops to 26°C and restarts when the temperature rises back to 30°C. How to set it?
Step 1: Confirm the working mode is Cooling Mode (Start Temperature > Stop Temperature).
Step 2: Press the Settings button to enter the internal menu, select P0 and press the Settings button to set the value of P0 to 30°C.
Step 3: Press the Settings button to enter the internal menu, select P1 and press the Settings button to set the value of P1 to 26°C.
Tip:
Heating Mode Setting Method
Setting Key Principle:
Setting Method:
Usage Case:
Control a water heater. The heating stops when the temperature reaches 50°C and restarts when the temperature drops back to 40°C. How to set it?
Step 1: Confirm the working mode is Heating Mode (Start Temperature < Stop Temperature).
Step 2: Press the Settings button to enter the internal menu, select P0 and press the Settings button to set the value of P0 to 40°C.
Step 3: Press the Settings button to enter the internal menu, select P1 and press the Settings button to set the value of P1 to 50°C.